The readout timing for PL-X cameras with Sony sensors varies, depending on the camera, its selected mode of operation, and bit output.


Normal Operating Mode


In the normal operating mode, the readout timing for the PL-X cameras with Sony sensors depends only on their bit output; Otherwise it is fixed. Readout timing for each of these cameras is summarized in the table below


Readout times in normal operating mode


CameraBit outputReadout time
PL-X9578 bit4.563 ms
12 bit7.111 ms
PL-X95128 bit15.152 ms
12 bit21.091 ms
PL-X95208 bit12.034 ms
12 bit17.015 ms
PL-X95248 bit14.336 ms
12 bit20.791 ms


Fixed Frame Rate Mode


In the special operating mode - Fixed Frame Rate mode (FFR), the readout timing for PL-X cameras with Sony sensors depends on the value of the region of interest (ROI) height parameter, and their maximum 1H period, which also changes depending on the bit output. Thus, readout timing for each camera can be calculated as follows


Readout time = ROI_height * 1H_max


Where: 1H_max for each camera is summarized in the table below


Maximum of 1H period for PL-X cameras with Sony sensors


CameraBit output1H_max
PL-X9578 bit2.0740 us
12 bit3.2323 us
PL-X95128 bit5.0505 us
12 bit7.0303 us
PL-X95208 bit2.6667 us
12 bit3.7710 us
PL-X95248 bit3.1111 us
12 bit4.5120 us