Debounce Delay

The debounce delay allows for non-TTL signals (slow and/or noisy edges) to be used in the trigger input.  The delay can be adjusted using the Trigger Debounce Tool.


Trigger Parameters


PL-B740 Trigger Parameters


ModeTypePolarityDelayParameter

0

Free-Running/ Hardware/ Software

Pos / Neg

0 - 2.5 sec

N/A

1

Free-running/ Hardware/ Software

Pos / Neg

0 - 2.5 sec

N/A

2

Free-Running/ Hardware/ Software

Pos / Neg

0 - 2.5 sec

2 - 100 triggers

3

Free-Running/ Hardware/ Software

Pos / Neg

0 - 2.5 sec

1 - 100 frame periods

14 

Free-Running/ Hardware/ Software 

Pos / Neg 

0 - 2.5 sec 

1 - 100 frames 


(all Trigger delay times are in steps of 10 usec)


PL-B770 Trigger Parameters


ModeTypePolarityDelayParameter

0

Free running/ Hardware/ Software

Pos / Neg

0 - 2.5 sec

N/A

14

Free-running/ Hardware/ Software

Pos / Neg

0 - 2.5 sec

1 - 1000 frames


(all Trigger delay times are in steps of 10 usec)

 

PL-B780 Trigger Parameters


ModeTypePolarityDelayParameter

0

Free-Running/ Hardware/ Software

Pos / Neg

0 - 2.5 sec

N/A


(all Trigger delay times are in steps of 10 usec)


GPO Parameters


PL-B740 GPO Parameters


ModePolarityParameter1Parameter2Parameter3 

Strobe

Pos / Neg

0 - 2.5 sec delay

10 usec - 2.5 sec duration

N/A

Normal

Pos / Neg

N/A

N/A

N/A

Pulse

Pos / Neg

1 - 1000 Pulses

10 usec - 100 msec duration

10 usec - 100 msec gap

Busy

Pos / Neg

N/A

N/A

N/A


(all GPO time parameters are in steps of 10 usec)


PL-B770 GPO Parameters


ModePolarityParameter1Parameter2Parameter3

Strobe

Pos / Neg

0 - 2.5 sec delay

10 usec - 2.5 sec duration

N/A

Normal

Pos / Neg

N/A

N/A

N/A

Busy

Pos / Neg

N/A

N/A

N/A

Flash Window

Pos / Neg

N/A

N/A

N/A


(all GPO time parameters are in steps of 10 usec)

 

PL-B780 GPO Parameters


Mode 
PolarityParameter1Parameter2Parameter3

Strobe

Pos / Neg

0 - 2.5 sec delay

10 usec - 2.5 sec duration

N/A

Normal

Pos / Neg

N/A

N/A

N/A

Busy

Pos / Neg

N/A

N/A

N/A

Flash Window

Pos / Neg

N/A

N/A

>N/A


(all GPO time parameters are in steps of 10 usec)